Solutions
Concept:
Hydro Electric Power Output:
The theoretical amount of power generated when water with flow rate Q is allowed to fall through net head of H is equal to, , where γw is unit weight of water.
But as there is losses in various components of the plants like in pumps, turbines, pipes, so actual power output will be less than the theoretical output and their ratio is known as plant efficiency.
∴ P = η × Pth = η × γw × Q × H
Load Factor: It is the ratio of average load over a certain period to peak load over that period.
Calculation:
Given, Flow rate Q= 26 cumec =26 m3/s, Net head available, H = 20 m, Plant efficiency, η=0.6, unit weight of water, γw = 10 kN/m3 and load factor Lf = 0.75
∴ Power output (P) = ηγwQH = 0.6 × 10 × 26 × 20 = 3120 kW
∴ Ppeak = 4160 kW.
∴ Peak load generated in the plant is 4160 kW.